为什么在VB.NET中,当它在C#.NET中有效时,不能覆盖Interface ReadOnly属性?

(这与 this other question有关)

如果你定义一个只有一个getter的接口的接口(= VBO中的ReadOnly),你为什么要在用C#实现类而不是用VB实现类时定义setter?

我原以为它是在.NET级别定义的,而不是特定于语言的.

示例:对于此接口

'VB.NET
Interface SomeInterface

    'the interface only say that implementers must provide a value for reading
    ReadOnly Property PublicProperty As String

End Interface

要么

//C# code
interface IPublicProperty
{
    string PublicProperty { get; }
}

这是C#中的正确实现:

public class Implementer:IPublicProperty
    {
        private string _publicProperty;

        public string PublicProperty
        {
            get
            {
                return _publicProperty;
            }
            set
            {
                _publicProperty = value;
            }
        }
    }

但这在VB.NET中无效

Public Property PublicProperty As String Implements SomeInterface.PublicProperty
    Get
        Return _myProperty
    End Get
    Set(ByVal value As String)
        _myProperty = value
    End Set
End Property

更新2015/04/23

原来这个功能是VB14的一部分!
Languages features in C# 6 and VB 14New Language Features in Visual Basic 14

ReadOnly interface properties can be implemented by ReadWrite props
This cleans up a quirky corner of the language. Look at this example:

06004

Previously,if you were implementing the ReadOnly property I.P,then
you had to implement it with a ReadOnly property as well. Now that
restriction has been relaxed: you can implement it with a read/write
property if you want. This example happens to implement it with a
read/write autoprop,but you can also use a property with getter and
setter.

请注意,假设VB.NET和C#是使用不同口音的同一种语言 – 它们不是.

因为VB.NET要求实现接口成员以具有该Implements子句,所以说明它正在实现哪个成员. C#允许您显式实现接口成员(类似于VB.NET的SORT OF),或隐式实现(没有VB.NET等效).因此,实际的C#版本是

public class Implementer : IPublicProperty
{
    private string _publicProperty;

    string IPublicProperty.PublicProperty    // explicit implementation
    {
        get
        {
            return _publicProperty;
        }
        set
        {
            _publicProperty = value;
        }
    }
}

这确实给出了一个错误:

error CS0550: ‘ConsoleApplication171.Implementer.ConsoleApplication171.IPublicProperty.PublicProperty.set’ adds an accessor not found in interface member ‘ConsoleApplication171.IPublicProperty.PublicProperty’

版权声明:本文内容由互联网用户自发贡献,该文观点与技术仅代表作者本人。本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如发现本站有涉嫌侵权/违法违规的内容, 请发送邮件至 dio@foxmail.com 举报,一经查实,本站将立刻删除。

相关推荐


Format[$] ( expr [ , fmt ] ) format 返回变体型 format$ 强制返回为文本 -------------------------------- 数字类型的格式化 --------------------------------     固定格式参数:     General Number 普通数字,如可以用来去掉千位分隔号     format$("100,1
VB6或者ASP 格式化时间为 MM/dd/yyyy 格式,竟然没有好的办法, Format 或者FormatDateTime 竟然结果和系统设置的区域语言的日期和时间格式相关。意思是尽管你用诸如 Format(Now, "MM/dd/yyyy"),如果系统的设置格式区域语言的日期和时间格式分隔符是"-",那他还会显示为 MM-dd-yyyy     只有拼凑: <%response.write
在项目中添加如下代码:新建窗口来显示异常信息。 Namespace My ‘全局错误处理,新的解决方案直接添加本ApplicationEvents.vb 到工程即可 ‘添加后还需要一个From用来显示错误。如果到这步还不会则需要先打好基础啦 ‘======================================================== ‘以下事件
转了这一篇文章,原来一直想用C#做k3的插件开发,vb没有C#用的爽呀,这篇文章写与2011年,看来我以前没有认真去找这个方法呀。 https://blog.csdn.net/chzjxgd/article/details/6176325 金蝶K3 BOS的插件官方是用VB6编写的,如果  能用.Net下的语言工具开发BOS插件是一件很愉快的事情,其中缘由不言而喻,而本文则是个人首创,实现在了用V
Sub 分列() ‘以空格为分隔符,连续空格只算1个。对所选中的单元格进行处理 Dim m As Range, tmpStr As String, s As String Dim x As Integer, y As Integer, subStr As String If MsgBox("确定要分列处理吗?请确定分列的数据会覆盖它后面的单元格!", _
  窗体代码 1 Private Sub Text1_OLEDragDrop(Data As DataObject, Effect As Long, Button As Integer, Shift As Integer, X As Single, Y As Single) 2 Dim path As String, hash As String 3 For Each fil
  Imports MySql.Data.MySqlClient Public Class Form1 ‘ GLOBAL DECLARATIONS Dim conString As String = "Server=localhost;Database=net2;Uid=root;Pwd=123456;" Dim con As New MySqlConnection
‘導入命名空間 Imports ADODB Imports Microsoft.Office.Interop   Private Sub A1() Dim Sql As String Dim Cnn As New ADODB.Connection Dim Rs As New ADODB.Recordset Dim S As String   S = "Provider=OraOLEDB.Oracl
Imports System.IO Imports System.Threading Imports System.Diagnostics Public Class Form1 Dim A(254) As String    Function ping(ByVal IP As Integer) As String Dim IPAddress As String IPAddress = "10.0.
VB运行EXE程序,并等待其运行结束 参考:https://blog.csdn.net/useway/article/details/5494084 Private Declare Function WaitForSingleObject Lib "kernel32" (ByVal hHandle As Long, ByVal dwMilliseconds As Long) As Long Pr
今天碰到一个问题,登陆的时候,如果不需要验证手机号为空,则不去验证手机号 因为登陆的时候所有的验证信息都存放在一个数组里 Dim CheckUserInfo() As String ={UserBirthday, SecEmail, UserMob, UserSex, RealNameFirst, RealName, CheckCardID, CheckCardType, Contactemail
在VB6.0中,数据访问接口有三种: 1、ActiveX数据对象(ADO) 2、远程数据对象(RDO) 3、数据访问对象(DAO) 1.使用ADO(ActiveX Data Objec,ActiveX数据对象)连接SQL Server 1)使用ADO控件连接 使用ADO控件的ConnectionString属性就可以连接SQL Server,该属性包含一个由分号分隔的argument=value语
注:大家如果没有VB6.0的安装文件,可自行百度一下下载,一般文件大小在200M左右的均为完整版的软件,可以使用。   特别提示:安装此软件的时候最好退出360杀毒软件(包括360安全卫士,电脑管家等,如果电脑上有这些软件的话),因为现如今的360杀毒软件直接会对VB6.0软件误报,这样的话就可能会在安装过程中被误报阻止而导致安装失败,或者是安装后缺乏很多必须的组件(其它的杀毒软件或安全卫士之类的
Private Sub Form_Load() Call conndb End Sub Private Function conndb() Dim cn As New ADODB.Connection Dim rs As New ADODB.Recordset Dim strCn, sql As String Dim db_host As String Dim db_user As String
  PPSM06S70:  Add  moddate  EDITSPRINTJOB:  MAX(TO_CHAR(ETRN.MODDATE, ‘yyyy/mm/dd/HH24:MI AM‘)) ACTUAL_SHIPDATE   4.Test Scenario (1) :Query SQL Test DN:8016578337 SELECT CTRN.TKCTID TRUCK_ID,        
  沒有出現CrystalReportViewer時,須安裝CRforVS_13_0. 新增1個數據集,新增1個數據表,添加二列,列名要和資料庫名一樣. 修改目標Framework 修改app.config, <startup >改成<startup useLegacyV2RuntimeActivationPolicy ="true">  CrystalReport1.rpt增加數據庫專家 在表單
Imports System.Threading Imports System Public Class Form1 Dim th1, th2 As Thread Public Sub Method1() Dim i As Integer For i = 1 To 100 If Me.Label1.BackColor =
Friend Const PROCESS_ALL_ACCESS = &H1F0FFF = 2035711 Friend Const PROCESS_VM_READ = &H10 Friend Const PROCESS_VM_WRITE = &H20 Friend Const PAGE_READONLY = &H2 Friend Const PAGE_READWRITE = &H4 Friend
以下代码随手写的 并没有大量测试 效率也有待提升 如果需要C#的请自行转换 Function SplitBytes(Data As Byte(), Delimiter As Byte()) As List(Of Byte()) Dim i = 0 Dim List As New List(Of Byte()) Dim bytes As New
Imports System.Data.SqlClient Public Class Form1 REM Public conn1 As SqlConnection = New SqlConnection("server=.; Integrated Security=False;Initial Catalog= mydatabase1; User ID= sa;password")